Semiconductor Packaging Equipment Optimization

Update:2018-05-23 17:44:13Clicks:431 times
More>>

Project Control Requirement by Client:

This system includes multi stations and it requires diode polarity resolution for different bagging process. Each station needs to distinguish between different diode polarities. After the automation judgment is completed, the steering should be performed and the material should automatically fed and discharged.

Control Target : The system needs6 axis motion control, more than 400 IO points.

Original solutions by the client: Two 4-axis PCI motion control cards connected with 8 pcs IO cards using PCI slot as interface.

Alps Motion upgrade solution:

A 6-axis motion control card connect 4pcs extension network I/O cards, each comprises of 48 in and 32 out interface. We only use one PCI slot. By this method, it could perform low-power consumption as well as reduce the CPU processing requirement of the original industrial computer.